Products Polypropylene concrete fiber Macro synthetic fiber Buy concrete fiber Applications Calculators About us Technical notes Contact Request a quote

Precast concrete fiber

Fewer cracked units. Lower rejection rate. More saleable production.

In a precast yard the expensive failure is not the concrete — it is the unit that gets cast, cured, handled and then written off. Whether a few points off the rejection rate covers the fiber depends on what a cubic metre of your production is worth. The arithmetic is below, and it does not always come out in the fiber's favour.

The expensive problem

Every rejected unit is fully loaded cost

A unit that fails at demoulding has already consumed cement, mould time, labour, curing energy and yard space.

  • Cracks at demoulding, before the unit has earned anything
  • Handling and stacking damage in the yard
  • Transport damage discovered at the far end of a delivery
  • Lifting stresses in thin architectural sections
  • Rust bleed staining facade panels years after installation
  • Mould occupied by a unit that will never be sold
  • Rework, replacement and a delivery programme that slips
Cutaway of fiber-reinforced precast concrete facade panels

The Polyguard solution

PrecastGuard PG PC-40 for thin, handled sections

PrecastGuard is dosed for sections that have to survive demoulding, stacking, transport and lifting. The fibers bridge micro-cracking and improve crack control during demoulding, stacking, transport and lifting, and because polypropylene does not corrode, it eliminates the rust bleed and staining that comes from the reinforcement it replaces.

Grade
PG PC-40
Fiber length
40 mm
Typical dosage
2–5 kg/m³
Surface
No rust bleed

What comes off the bill

Where a precast plant gets the money back

  • Units written off at demoulding and in the yard
  • Mould turns lost to a unit that will be scrapped
  • Rework, patching and cosmetic repair labour
  • Replacement transport for damaged deliveries
  • Light mesh in thin non-structural sections, where the design permits
  • Warranty and remediation cost from rust-stained facades

The comparison that matters

Fiber cost against scrap cost

Take annual production value, multiply by the current rejection rate, and compare that with the fiber cost of the same production. Which of the two is larger depends entirely on the value density of what you cast — the production value carried by each cubic metre.

Cutting a 4% rejection rate to 2.5% on 4,000,000 of annual production returns 60,000 a year. Dosing that same production costs about 91,800 — so on these figures the rejection saving alone does not cover the fiber, and the rest of the case has to carry it.
Rejected & reworked unitsFully loaded cost per unit
SteelTransportCutting & lapsChairsLabourSupervisionDelay
PrecastGuard, dosedFiber across the same production
FiberDosing

Steel purchaseTransport & storageCutting & lap wasteChairs & spacersPlacing labourSupervisionPlacement delayPolyguard fiber, dosed in the mix

The figures are arithmetic on your own numbers, not a performance claim. Actual reduction depends on section geometry, mix, dosage, handling regime and mould design.

Two horizons

Yard economics and building economics

In the yard

  • Fewer units lost between demoulding and delivery
  • More saleable output from the same moulds and shifts
  • Less patching, less cosmetic rework, fewer credit notes
  • Thinner sections viable where light steel was the constraint

In the building

  • No rust bleed on exposed architectural surfaces
  • Cover driven by durability, not by steel protection
  • Better performance in chloride and sulfate exposure
  • Fewer facade remediation claims over the building's life

Worked example — rejection rate arithmetic

Illustrative figures. Put your own production value and rejection rate in.

Annual production value
4,000,000
Current rejection rate
4.0% → 160,000 written off
After improvement
2.5% → 100,000 written off
Recovered per year
60,000
Annual concrete volume
9,000 m³
PrecastGuard at 3 kg/m³, 3.40 /kg
≈ 91,800
Fiber cost per m³
10.20
Production value per m³
4,000,000 ÷ 9,000 ≈ 444
Net position on rejection alone
−31,800 — the saving does not cover the fiber here
Break-even value per m³
≈ 680 — above this, a 1.5-point cut pays for the dose on its own

That is the honest shape of it: at 444 per cubic metre this is low-value production, and the rejection line alone does not pay for the dose. On architectural and facade work, where a cubic metre carries several times that value, the same 1.5 points clears the fiber comfortably. Either way the rejection saving is one line of the case, not all of it — rework labour, replacement transport, light mesh removed from thin sections and avoided facade remediation sit alongside it. Run the arithmetic on your own production value and loss rate before you compare fiber prices.

Your numbers

What a point of rejection is worth

Every figure below is yours. The calculator will tell you the rejection cut you need before the dose pays for itself — and it will say so plainly when your own target does not reach it.

Precast production ROI calculator

Rejection, rework and handling damage against the annual fiber investment.

CurrencyUSD

Annual production

Current losses

Polyguard

Result

Annual production value
—
Current rejection loss
—
Rework cost
—
Handling & transport loss
—
Annual fiber investment
—
Fiber cost per m³
—
Rejection cut needed to break even (points)
—
Recovered production value
—
Rework & claims avoided
—
Return on the fiber spend
—
Months of benefit to cover the dose
—
Net annual benefit
—

Indicative only. Rework and claims are assumed to fall in the same proportion as rejection — that is your assumption to accept, not a Polyguard claim. The dosage must be confirmed by structural design and a trial mix.

Questions plant managers ask

Production and finish

Does fiber show on an architectural face?
At the specified dosage and with normal vibration, fibers stay below the surface skin. We recommend a trial on your own mould and mix before a facade contract.
Does it slow the production cycle?
No. It is a batching change, not a process change. Mixing time may increase slightly to guarantee dispersion; we give you the sequence.
Can it replace the cage in a structural unit?
No. Structural reinforcement stays with the designer. Fiber addresses handling, shrinkage and crack control, and in some non-structural thin sections can replace light mesh.
What about self-compacting mixes?
Compatible, with dosage and rheology checked on a trial batch. Send the mix design and we will advise before you order.

Price the whole panel cost, not just the mesh

Send the drawing, the exposure class and the loading. You get a dosage recommendation, a data sheet and an installed-cost comparison against your current specification.

Speak to a fiber engineer

Technical desk

Send this result to an engineer

Your calculation is attached to this enquiry automatically. Add your name and email — and a note of your own, if you want one.

See what gets sent